Axial sample deformation is applied by driving the high sensitivity FRT in controlled strain sinusoidal oscillation, unlocking all new capabilities for solids testing. In. TA Instruments strives to deliver high quality software products and instruments. Wide temperature range This unique motor technology combines powerful rare-earth magnets with a frictionless flexural suspension for the most precise force and displacement control over a wide range of frequencies and amplitudes. Testing can be conducted in both static The sample demonstrates the classic linear region in the beginning of the test in the left of the plot and a very long ductile failure over the middle and right of the plot. The DSC 250 and DMA 850 work together to bridge the gap between formulation changes and their impact on final composite product performance. TA Instruments ElectroForce DMA 3200 High Force DMA. . Cantilever modes are also known as clamped orsupported bending modes because the support anddeformation points are mechanically fixed to the sample. AutoStrain is also used to adjust the input strain, maintaining an optimal oscillation force under all conditions. Unmatched versatility. View DMA BrochureDMA AccessoriesRequest a Quote. The wide range of TA Dynamic Mechanical Analyzers is not only the best-selling in the world, but also covers the widest range of forces and applications. Capable of real-time control using a variety of sensors to perform a wide range of tests. 3-Point Bending, Dual/Single Cantilever, FilmTension, Compression, 3-Point Bending:5, 10, 15 mm (Fixed-Length), Up to 15 mm (Width), and Up to 7 mm (Thickness)Dual/Single Cantilever:35/17.5 mm (Fixed-Length), Up to 15 mm (Width), and Up to 5 mm (Thickness)Film Tension:5 to 30 mm (Length), Up to 8 mm (Width), and Up to 2 mm (Thickness)Compression:Up to 15 and 40 mm (Diameter), Up to 10 mm (Thickness), TA Instruments109 Lukens Dr.New Castle, DE 19720Phone: 302-427-4000Fax: 302-427-4041Email:answerman@tainst.comWebsite:http://www.tainstruments.comApplication Hotline: 302-427-4070, Irvine Materials Research Institute - Driving Materials Innovation, Laboratory for Electron and X-ray Instrumentation, Center for Transmission Electron Microscopy, Scanning Electron Microscopy & Focused Ion Beam, Low-Mass and High-Stiffness Sample Clamps, Viscoelastic Properties (E, E, and tan ). WinTest is a high-performance software package that is used to operate all TA ElectroForce mechanical test instruments. FB
m!IqkPl ?;-E_ All rights reserved. With two ovens, three cooling accessories and a wide range of grips you can create the perfect configuration for your characterization needs. ;@Dlp4btbnMzV='&d:84z@6dWJtT?c^"dw(T^ C2
CmR e )mycR5q((? This download contains the necessary files to update your Orchestrator software from any previous version to v7.2.0.4. Detectable Information: Glass transitions, melting, crystallization, phase changes, heat capacity, cure kinetics, oxidative induction time. Examples of high force DMA capabilities are shown in the figures to the right. The sample dimensions were a diameter of 10 mm and thickness of 20 mm. Unique TuneIQ and Controlled Stop help users harness the acceleration and power of ElectroForce motors by simplifying tuning tasks. New features such as automated calibration routines, multiple calibration sets, real-time test method editing, and inter-laboratory data and test method sharing provide unmatched flexibility, while one-click analysis and custom reporting raise productivity to new levels. The versatility of the DMA 1 allows applications to be performed in the optimum measurement configuration. Now in addition to the most sensitive and accurate rotational shear measurements, the DHR can deliver accurate linear Dynamic Mechanical Analysis (DMA) data. The height and area under tan curve give an indication of the total. This intuitive software includes a wide variety of plotting tools, some of which include multi-axis plotting, smart default and user-customizable graph settings, drag-and-drop overlay, and user-defined variables. One-, Two-, or Three-stage refrigeration systems that achieve temperature ranges down to -40 C, -90 C or -120 C, Sealed system eliminates the need for liquid nitrogen cooling, Enables cycling, MDSC, controlled, and ballistic cooling experiments, Safe, convenient, and continuous cooling operation for your laboratory needs, Control multiple instruments with a single PC and software package. Data from RPA, MDR, Mooney Viscometer, Hardness, and Density tests can be organized, compared, and analyzed by material type, inventory order, date, and more. Monotonic testing, also known as tensile testing, is also useful for evaluating strength and deformation response. endobj
7 0 obj
Axial DMA complements solid torsion testing by providing a direct measure of the modulus of elasticity, or Youngs Modulus (E). This efficient, quiet, and lubrication-free motor technology allows the DMA 3200 to be used virtually anywhere; from lab to production floor, or from the cleanroom to office space. Unlike traditional rolling or plain bearings that introduce noise and friction into the measurement, air bearings have the added benefit of preserving the high performance attributes of the friction-free ElectroForce linear motor. A Dynamic Mechanical Analyzer is a mechanical instrument that applies specific displacement or force to a sample and very accurately quantifies its force versus displacement response. The FCO comes standard with a convenient long-life internal LED light and viewing port. Better sensitivity, resolution, repeatability and industry leading baseline performance, enable detection of the weakest thermal transitions and the most accurate enthalpy and specific heat capacity. Storage modulus, loss modulus, Tan delta, glass transition temperature (Tg), sub-Tg molecular motions (beta and gamma relaxations.). endobj
The DMA 3200 combines decades of cutting-edgefatigue and world-leading Dynamic Mechanical Analysistechnologies into a unique and highly versatile testingplatform. The DMA 3200 has a wide range of accessories you can choose from and combine to deliver the results you need. This download is a full version of the software and documentation. TA Instruments DMA Q-800 Standard Operating Procedure 3/31/2016 Safety: User safety: This tool uses Liquid Nitrogen (LN2) for cooling. This ensures the most durable and reliable performance; proven over billions of cycles through decades of maintenance-free use in ElectroForce fatigue test instruments. The DMA 3200 motor delivers a force output of up to 500 N and controlled displacements ranging from 1 micron to 13 mm. endobj
Available in sample lengths of 8 mm, 20 mm, and 35 mm, the cantilever clamps can be used in single or dual configurations. Building on superior technologies of the world's best-selling DMA, improvements in every aspect of DMA performance deliver the most accurate and reproducible measurement of mechanical properties over a wide temperature range. Its as easy as 1, 2, 3. With this combination you will quickly get the results you need and minimize downtime in your laboratory. The ultra-stiff design of the 3200 ensures superior data accuracy. Thermal Conductivity & Diffusivity Analyzers, High Pressure Thermogravimetric Analyzers (HP-TGA), Discovery Hybrid Rheometer (DHR) Accessories, Nano Differential Scanning Calorimeter (DSC), ElectroForce Mechanical Testing Accessories, Thermal Conductivity & Diffusivity Brochures, ElectroForce Mechanical Testing Brochures, High Force DMA & Fatigue Test Instruments, 8/4* mm (L), Up to 15 mm (W) and 5 mm (T), 20/10* mm (L), Up to 15 mm (W) and 5 mm (T), 35/17.5* mm (L), Up to 15 mm (W) and 5 mm (T), 5,10, or 15 mm (L), Up to 15 mm (W) and 7 mm (T), 5 to 30 mm (L), Up to 8 mm (W) and 2 mm (T), 5 to 30 mm (L), 5 denier (0.57 tex) to 0.8 mm diameter, Fixed at 15 mm (L), Up to 8 mm (W) and 2 mm (T), 5, 10, or 15 mm (L), Up to 15 mm (W) and 7 mm (T). The NPC is asmall, economical, and effective option for laboratories that have basic cooling requirements. Automated filling of the GCA tank can be programmed to occurafter the scan is complete. Standard FCO clamps, constructed of 17-4 stainless steel, are for use to a maximumtemperature of 500C, with optional clamps available for extended use to 600C. Thermal Q Series Installation Requirements, Setting up Windows 10 for Thermal Advantage, This download is a full version of Advantage. The top figure shows a temperature ramp on a bar of Polycarbonate at a heating rate of 3C/min and strain of 0.4%. Its wide range of speed and force make it useful for both fatigue and quasi-static testing. Measurements in the bending direction allow you to characterize product performance properties such as impact resistance, blending homogeneity, structural performance, and glass transition temperature measurements. In general, the maximum cooling rate is afunction of the installed clamp and the thermal characteristics of the sample. All environmental systems and accessoriesare designed specifically for high performance DMA measurements and seamless integrationand are manufactured by TA Instruments. Various material, component or device characteristics can be measured with the DMA 3200, supporting many types of dynamic or static strength studies. Visual guides aid in aligning film samples and integrated supports simplify fiber testing. Dynamic mechanical analysis (DMA) is the most preferred widely used and thermal analysis technique for determining the glass transition temperature ( Tg ) of polymer matrix composites because it is more sensitive to Tg measurements than other thermal analysis techniques. The DMA-RH Accessory contains the humidifier and electronics whichcontinuously monitor and control temperature and humidity of the sample chamber. It is ideal for testing solid bars of stiff materials, such Supported Operating Systems: 64-bit version of Windows 7, 8, & 10 Ultimate, Windows 11, Enterprise & Professional. The article below discusses the benefits of the DMA 2980 design. The Standard Furnace for the DMA850 is a wide-range bifilar wound furnace that provides uniform temperature control from -160C to 600 C. In addition, your input regarding our software products is important to us. This ensures the most durable and reliable performance; proven over billions of cycles through decades of maintenance-free use in ElectroForce fatigue test instruments. A rotational rheometer can perform flow measurements to test the viscosity of a liquid as a function of time, temperature shear rate or shear stress. How the DSC 250 Auto and DMA 850 together will benefit your lab: Changes to resin formulation through concentration changes and ingredient swapping has direct impact on the curing kinetics, working time, and performance of the cured composite. 4 0 obj
DSC and TGA Intelligent Analysis provides specialist-level analysis with a single click. Single and Dual Cantilever (Clamped Bending). In the attempt to facilitate the transition to the current Discovery Series, TA is going to offer a trade-in program with exclusive packages. It can also be used to measure expansion or contraction, tack testing for adhesives, compression set of rubber o-rings, and much more. Competitive instruments employing air bearings and passive normal force measurements are inherently incapable of such measurements due to design limitations. Supported Operating Systems: 64-bit version of Windows 11 or 10 Ultimate, Enterprise & professional. ElectroForce Dynamic Mechanical Anaylsis (DMA) software provides a flexible platform for advanced viscoelastic property measurement for a variety of materials, including engineered materials, such as elastomers, composites as well as biomaterials. During this test, forces required to apply 20%strain, which is equivalent to 5 mm, are approaching 60 N. These results highlight both the high force and exceptional displacement control of the DMA 3200. HADS is an ultra-performance optical device capable of friction-free, low-noise measurements with nanometer resolution at high-speeds. Condition: New. This efficient, quiet, and lubrication-free motor technologyallows the DMA 3200 to be used virtually anywhere; from labto production floor, or from the cleanroom to office space. A custom-designed humidity and temperature chamber optimized for mechanical measurements provides stable, reliable control of temperature and humidity over a widerange of operating conditions. <>/ExtGState<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>>
They also add highly durable and fast fatigue test methods, delivering as much as 15,000 Newtons of force in the largest HF-DMA model. Open the catalog to page 8 In addition, the frictionless, moving-magnet design eliminatesfailure points that exist in other motor designs, such as movingwires and bearing degradation. Complete array of geometries for axial testing: Axial Force Control tracks material stiffness and automatically adjusts static load, Superior temperature control with the Environmental Test Chamber (ETC) up to 600 C, Air Chiller Systems provide liquid nitrogen-free cooling to 85 C, Optional sample visualization with ETC camera, Compatible with Relative Humidity accessory for complete environmental control of temperature and humidity. Four different clamps with five measurement modes can be selected based on material stiffness and dimension. Dynamic Mechanical Analyzer DMA 850 TA Instruments Applications: Inquire Measurement Mode (s): Inquire Temperature Range: Standard Furnace: -160C to 600C, RH Accessory: 5C to 120C Heating / Cooling Rates: Inquire Get Quote Compare Zoom In Dynamic Mechanical Analyzer High Force DMA 3200 TA Instruments Applications: Material testing The online DMA course is designed to give a basic overview of DMA technology. TA Instruments TRIOS software seamlessly transfers DMA data from WinTest, providing experimentalists with the industrys leading tool for analyzing and presenting DMA data. During DMA measurements, the position of the active bearing is directly controlled to impose oscillatory linear deformation on the sample. Materials such as polymers exhibit viscoelastic behavior which is directly related to molecular structure and formulation differences. Note: This software supports TAM Air instruments. The applied deformation is parallel to the sample thicknessand the resultant deformation is simple shear. endobj
*Actual performance may vary slightly depending on laboratoryconditions and the clamping system installed. This capability is highlighted in the plot showing a temperature ramp on 50m thick PET film tested using tension geometry over a temperature range of -100 C to 250 C. Advantage Software v5.5.24. Single and Dual Cantilever: Evaluation of cure and all purpose, 3- Point bend (for medium to high modulus), Films: 8- 20 mm L, 5- 6.5 mm W and up to 2 mm T, Shear deformation of gels, viscous resins and adhesives: 10mm x 10 mm square of up to 4 mm thick, Low-medium modulus (foams), 15- or 40-mm diameter and up to 10 mm thick. In addition to quantifying viscoelastic properties of materials, DMA can also quantify finished component and product characteristics, reflecting the important contribution that processing has on end-use product performance. Building on superior technologies of the world's best-selling DMA, improvements in every aspect of DMA performance deliver the most accurate and reproducible measurement of mechanical properties over a wide temperature range. The DMA 3200 features patented ElectroForce linear motor technology enabling a single instrument to deliver unequalled performance and data accuracy. Examples of these capabilities are shown in the figures to the right. In this mode, the sample is deformed around three-pointcontacts at both ends and its middle. Enabling Fatigue and Quasi-static Testing. Our websites may use cookies to personalize and enhance your experience. Range-150 C - 500 C : Sensor Output: Modulus Loss Factor (tan delta) Frequency Range: 0.001 to 1000 Hz : Tan Delta Range: Displacement Range () 1.6 mm : Temperature Range-150 C . The DMA 3200 combines decades of cutting-edge fatigue and world-leading Dynamic Mechanical Analysis technologies into a unique and highly versatile testing platform. The bottom figure shows strain sweeps on two cylindrical rubber samples, tested using compression clamps, at a temperature of 30C and frequency of 10 Hz. A rotational rheometer is used to measure viscosity (eta) and viscoelasticity (G, G and Tan delta) properties of a material. One-Touch-Away User Interface enhances usability and access to data on the instrument. In mechanical testing, an instrument design with highly stiff components, such as the frame, connecting components and sample clamps, are criticalfor measurement accuracy. The hydrogels were clamped between a parallel-plate compression clamp with a diameter of 0.6 cm. Most materials, components, and devices are exposed to repeated loading conditions during their use and this loading causes fatigue of the material. Sample spans of 5 mm, 10 mm, 15 mm, 20 mm, and 50 mm are available to accommodate a wide range of sample stiffness and specimen sizes. TAM Air. The TA Instruments DMA 2980 is based on a distinct patent pending design that adjusts the combination of critical components. ITCRun NanoAnalyze DSCRun MC-DSCRun Cleaning Station. A range of standard test definition waveforms including sine, triangle, square, ramps, Create customized combinations of waveforms for multiple segment tests and utilize other features including conditional branching, relative move, and embedded data acquisition, with block waveform programming. TA Instruments invites you to experience the ultimate in Dynamic Mechanical Analyzers, the Discovery DMA 850. The larger volume of the LSO is ideal for configuring the DMA 3200 with customized clamping solutions for unique applications. TA Instruments Menu Products Products Thermal Analyzers Differential Scanning Calorimeters (DSC) Thermogravimetric Analyzers (TGA) High Pressure Thermogravimetric Analyzers (HP-TGA) Simultaneous Thermal Analyzers (SDT) Dynamic Mechanical Analyzers (DMA) Thermomechanical Analyzers (TMA) Sorption Analyzers (SA) Dilatometers Horizontal Dilatometers Optional TRIOS Guardian with electronic signatures for audit trail and data integrity. Modulated DSC (MDSC) for the most efficient separation of complex thermal events. Mechanical fatigue testing provides insights on how and when materials, components, or devices fail when subjected to oscillating forces, or stresses. These results demonstrate the capabilitiesof the DMA 3200 design in several ways. Provided heating furnace with optional air or liquid nitrogen coolers allow for measurement from -150 up to 600 C. TA System DMA 1. Monitor test progress with up to 4 configurable real-time data, high-speed scopes.